BULLETIN 450-MR2-5
MASON INDUSTRIES | MASON-IND.COM
9
•
89
Pipe
Size
Face to
Face
Axial
Compression
Axial
Extension
Lateral
Deflection
Degrees
Angular
Degrees
Torsional
(in) (in) (in) (in) (deg) (deg)
1
1
/2 24 10
1
/2 5
1
/8 6 90 41
2 24 10
1
/2 5
1
/8 6 87 40
2
1
/2 24 10
1
/2 5
1
/8 6 84 34
3 24 10
1
/2 5
1
/8 6 81 32
4 24 10
1
/2 5
1
/8 6 76 25
5 24 10
1
/2 5
1
/8 6 70 26
6 24 10
1
/2 5
1
/8 6 66 23
8 24 10
1
/2 5
1
/8 6 57 19
10 28 10
1
/2 5
1
/8 6 50 18
12 28 10
1
/2 5
1
/8 6 45 15
14 28 13 6
3
/8 7
3
/8 47 15
16 28 13 6
3
/8 7
3
/8 43 13
18 28 13 6
3
/
8
7
3
/
8
39 14
20 28 13 6
3
/8 7
3
/8 36 14
24 36 15
3
/
4
7
1
/
2
8
3
/
4
36 12
30 36 15
3
/4 7
1
/2 8
3
/4 30 11
36 36 15
3
/
4
7
1
/
2
8
3
/
4
25 10
Pipe
Size
Face to
Face
Axial
Compression
Axial
Extension
Lateral
Deflection
Degrees
Angular
Degrees
Torsional
(in) (in) (in) (in) (deg) (deg)
1
1
/2 21 8
3
/4 4
3
/8 5 88 33
2 21 8
3
/4 4
3
/8 5 85 32
2
1
/2 21 8
3
/4 4
3
/8 5 81 28
3 21 8
3
/4 4
3
/8 5 78 25
4 21 8
3
/4 4
3
/8 5 71 20
5 21 8
3
/4 4
3
/8 5 66 21
6 21 8
3
/4 4
3
/8 5 60 19
8 21 8
3
/4 4
3
/8 5 52 15
10 24 8
3
/4 4
3
/8 5 45 14
12 24 8
3
/4 4
3
/8 5 39 12
14 24 10
7
/8 5 6
1
/8 41 12
16 24 10
7
/8 5 6
1
/8 37 11
18 24 10
7
/8 5 6
1
/8 34 11
20 24 10
7
/8 5 6
1
/8 31 11
24 31 13
1
/8 6
1
/4 7
3
/8 31 9
30 31 13
1
/8 6
1
/4 7
3
/8 25 9
36 31 13
1
/8 6
1
/4 7
3
/8 22 8
CONTROL RODS
Expansion Joints installed in piping
systems that are anchored on both
sides of connectors need no control
rods, providing piping movements
are within the tabulated allowables.
Expansion joints installed in unanchored
piping or connected to isolated equipment
must have control rods; those control rods must be properly
set so that allowable movements are not exceeded.
The number of control rods is determined by the maximum
working pressure of the pipeline, not the maximum pressure
rating of the joint. Use the convenient chart to the right to
specify. Control rods are designed for a 3:1 safety factor as is;
please use accordingly. For example, if a 24" 452 joint is
installed in a pipeline with a maximum pressure of 120 psig,
3 control rods are required. If the maximum pressure of the
pipeline is 220 psig, 5 control rods are required.
Pipe
Size
Arch
Height
Gusset
Thick-
ness
Rod
Dia.
Joint
Thrust
Area
Maximum Operation
Pressure (psig) for Specified
Number of Rods
(in) (in) (in) (in) (sq. in) 2 3 4 5 6
1
1
/
2
1
1
/
4
1
/
2
10 250 — — — —
2 1
3
/
8
5
/
8
13 250 — — — —
2
1
/2 1
3
/8
5
/8 16 250 — — — —
3 1
3
/8
5
/8 20 250 — — — —
4 1
3
/
8
5
/
8
28 250 — — — —
5 1
3
/8
5
/8 38 250 — — — —
6 1
1
/2
5
/8 50 250 — — — —
8 1
1
/
2
3
/
4
79 250 — — — —
10 1
3
/4
7
/8 113 250 — — — —
12 1
3
/4 1 154 240 250 — — —
14 1
1
/4
3
/4 1 214 174 250 — — —
16 1
1
/4
3
/4 1
1
/8 269 175 250 — — —
18 1
1
/4
3
/4 1
1
/8 330 143 211 250 — —
20 1
1
/4
3
/4 1
1
/8 398 117 175 234 250 —
24 1
1
/2 1 1
1
/4 573 100 150 201 250 —
30 1
1
/2 1
1
/4 1
1
/2 855 97 145 193 242 250
36 1
1
/2 1
1
/2 1
3
/4 1195 94 141 188 236 250
SERIES 450 CONTROL ROD CALCULATIONS
CAUTION
1. Do not install any of the products in this bulletin at
pressures or temperatures higher than the published
ratings.
2. 450 Butyl, EPDM & Viton
®
connectors are recommended
for intermittent (10 minute maximum exposure per hour)
250°F. service or continuous service at a maximum of
225°F. Use Mercer series 500, 600, HT500 or HT600 as
described in bulletin 500-MR7 (pages 9
•
90 - 9
•
97) for
continuous temperatures of 230°F and higher.
3. S eries 450 must be installed against standard
1
/16" raised
faced or flat faced flanges. Do not install them against
recessed flanges such as Victaulic without calling the
factory for proper steel filler flanges. If our rubber flanges
do not have full bearing, the expansion joint will be
damaged and leak or fail.
4. Initial misalignment should be kept to a minimum of
1
/8".
5. P ipe system flanges must be smooth and flat. Screw
in brass inserts such as those used in check valves can
damage the rubber faces if they project above the cast
flange face.
6. Water type check valves must exactly center on the rubber
flanges. Valve O.D. and I.D. should be checked for
conformance with raised face dimensions
7. C heck Chemical Resistance Guide CRG-MR1 (pages 9
•
59 -
9
•
68) for service elastomer compatibility.
Distributor:
Interflex Hose & Bellows Ltd. • www.interflex.co.uk
Ludlow Eco Park • Ludlow • Shropshire • SY8 1FF • United Kingdom
Tel.: +44 (0)1584 878500 • Email: enquiries@interflex.co.uk